Signal converters and signal conditioners are industrial instrumentation devices for analog signal processing. These devices convert industrial process signals into analog or digital signals to interface with industrial process automation equipment. These conditioners provide isolation, conversion, amplification, alarm management, display and control functions.
Discover our signal conditioners
In stock
ref : B3
Public price
191,00 €
Discounts available, please consult us
Request a quote
In stock
ref : B3-1
Public price
386,00 €
Discounts available, please consult us
Request a quote
In stock
ref : M3
Public price
285,00 €
Discounts available, please consult us
Request a quote
In stock
ref : 27U-1
Public price
275,00 €
Discounts available, please consult us
Request a quote
In stock
ref : 27U
Public price
65,00 €
Discounts available, please consult us
Request a quote
In stock
ref : M6DSN
Public price
275,00 €
Discounts available, please consult us
Request a quote
Using signal conditioners
Signal conditioners convert a field signal from various sensors into standard signal suitable for processing in PLC, DCS or PC-based systems.
to boost a signal to increase load drive capability,
to isolate a signal to stop ground loops.
More than 75,000 combinations of process signal I/O , power input and mounting configuration are selectable.
Additionally, Fuji Electric offers the broadest line of signal splitters available.
2 wire universal temperature transmitter - B3 model
Specifications
Input type and range selectable with the internal DIP switches and fine calibration using the front potentiometers
Define input during order : mV, V, T/C, RTD
Wide supply voltage range 12-45V DC
Isolated output
18 mm wide
Input configurable two-wire transmitters, DIN rail mounted
Universal inputs and isolated output: mV, PT100 resistance thermometer , Thermocouple , Potentiometer
HART®, HART® SI and PROFIBUS-PA
Model type
Input type DIP-programmable Hart® / Profibus RTD, insolated B3FR mV and V, isolated B3FV T/C K J T, isolated B3FT-1 T/C E R N, isolated B3FT-2 Universal, Hart® B3HU-0 Universal, Hart®, IS B3HU-2 Universal, Profibus-PA 27PM-0
Space-saving signal conditioners - M3LU
The M3LU is a programmable universal signal converter for DIN rail mounting, which does not require the use of a PC or a programming panel.
Local configuration with 3 keys on the front panel and jumper switches.
Specifications
Universal inputs :
Current input (0-20mA) or voltage (-10 to +10DC)
Thermocouple (K, E, J, T, B, R, S, C, N, U, L and P)
Resistance (Pt 100-1000, Ni 100-120, Ni508.4, Ni-Fe 604, Cu 10)
Potentiometer (0-4000Ω)
Current output (0-20mA) or voltage (-10 to +10DC)
T4-wires technology - External power supply : 9-36V DC or 85-264V DC 50/60Hz
Isolation Input / output : 1500V AC
Min/max scale fallback value in the event of thermocouple breakage
Optional frequency input,
Optional USB (COP-US) or serial (MCN-CON) configuration cable
Model type
Input type PC-programmable Frequency, isolated, 85-264Vac M3LPA2-M2/A Frequency, isolated, 9-36Vdc M3LPA2-R4/A Universal, isolated, 85-264Vac M3LU-M2/A Universal, isolated, 9-36Vdc M3LU-R4/A
Input loop powered isolator - M6DSN
DIN RAIL mounted Input loop powered isolator M6DSN are available with one or two channels.
Specifications
5,9 mm wide ultra-slim design
N° of channels : 1 and 2 channels
DIN rail mounting
Accuracy: ±0.1%
CE/UL and CUL approvals
Loop-powered design eliminates output loop power supply
4/20mA input
4/20mA output
2 wire universal temperature transmitter - 27U
The 27 SC converter is a head-mounted two-wire signal converter.
Specifications
Universal inputs: mV, thermocouple, RTD and resistance thermometer
Programming via PC Configurator (HART® version for 27HU model)
Programmable linearization table
ATEX / FM IS
SIL 2
Model type
Input type Converter type Programmable PC Hart® RTD, non-isolated 27R-0 RTD, non-isolated, IS 27R-2 RTD, insolated 27RS-0 RTD, isolated, IS 27RS-2 T/C, isolated 27TS-0 T/C, isolated, IS 27TS-2 Universal 27U-0 27HU-0 Universal, IS 27U-2 27HU-2 Potentiometer 27PM-0
Accurately transform your process signals into usable data with our purpose-built instruments
One or more fields contain an error. Please check and try again.
Thank you for your request. It has been sent.