High gauge pressure measurement
Fields of application
Designed for pressure monitoring in critical industrial applications such as oil & gas, cryogenics, hydraulic presses and test benches.
Features
The FKR gauge pressure transmitter is specially designed for industrial applications requiring reliable and accurate measurement of very high pressures, up to 70 MPa, i.e. 700 bar, 70,000 kPa or approx. 10,152 psi. Thanks to its piezoresistive silicon transducer and digital processing electronics, it offers excellent long-term stability and outstanding accuracy. It meets the most stringent safety requirements (SIL2/SIL3) and integrates easily into control systems thanks to its 4-20 mA output with HART™ protocol. Robust and adaptable, it is perfectly suited to harsh environments and critical processes under high stress, notably in hydrogen production systems, industrial hydraulic presses, plastic injection machines, supercritical steam plants, hydrotreating or hydrocracking units, hydraulic control of subsea valves, high-pressure cryogenics, high-pressure systems in civil nuclear power and CO₂ storage and distribution.
Type | Intelligent 4-20 mA Pressure transmitter with HART™ 7 protocol | |
Housing | L- or T-shaped housing | |
Measuring ranges [e.max.] | From 4.375 to 70 MPa | |
Measurement limit | -100 to 70,000 (kPa) | |
Permissible overpressure | 105 MPa | |
Weight per kg (without indicator) | 1,5 | |
Accuracy | From 1/10 to 1/1 of URL: ±0.065 % of span From 1/16 to 1/10 of URL: ±(0.015 + 0.05 × 0.1 × URL/span) % of span | |
Materials in contact with the fluid | Membrane | Inconel® 625 (with or without gold plating) |
Connection | Stainless steel 318LN or Inconel® 625 | |
Sensor body | Stainless steel 316L or Inconel® 625 | |
Non-contact materials | Housing | Cast aluminum (polyester coating) or 316L stainless steel |
Filling fluid | Silicone or mineral oil | |
Stability | ±0.1% of upper range limit for 5 years | |
Elevation / Deletion | Zero offset: ±0.2% of max. scale (URL) | |
Scale setting range | From 1 to 1/16 of maximum scale | |
Measurement cycle | 40 ms | |
Communication protocol | HART™ 7 communication protocol only | |
Response time | Time constant: 80 ms Dead time: approx. 60 ms Total time ≈ 140 ms | |
Process temperature | From -40 to 100°C | |
Ambient temperature | From -40 to +85°C -20 to +80°C (with optional LCD unit) -40 to +60°C (with optional lightning arrester) | |
Storage temperature | From -40 to +90°C | |
Temperature effects | Zero offset: ±(0.075 + 0.125 × URL/extent) % / 28 °C Total effect: ±(0.095 + 0.0125 × URL/extent) % / 28 °C | |
Power supply | 10.5 to 45 V DC | |
Output signal / Load resistance | 4-20 mA / 250 Ω typical + HART™ (NAMUR NE 43 compliant) | |
Dielectric strength | 500 V AC for 1 min (between circuit and earth) | |
Insulation resistance | > 100 MΩ at 500 V DC (between circuit and ground) | |
Damping | Configurable from 0.04 to 32 seconds | |
Zero and span adjustment | Via external sensor screw, local three-button indicator or HART™ protocol | |
Electrical connections | M20×1.5" / 1/2 -14 NPT / Pg13.5 | |
Assembly | Direct or Ø60.5 mm tube mounting (U-bolt stainless steel 304L/316L) | |
Process connection | AutoClave F250C (F) or F250C (M) (adapter) or 1/4-18 NPT (F) (adapter) | |
Compatibility | CEM : EN 61326-1, EN 61326-2-3, EN 61326-3-1 ATEX/ IECEx / cCSAus : Intrinsically safe (Ex ia), Explosion-proof enclosure (Ex d), XP/IS/NI Division 1 and 2 | |
Options | Digital indicator, degreasing treatment, oxygen service, chlorine service, additional stainless steel identification plate |
Gauge pressure transmitter - high pressure - 70 MPa - FKR
Reference : FKR-06