Fields of application
The FKE level transmitter can be used for any level measurement, whether in corrosive or non-corrosive liquids and in tanks that are either closed or open to the atmosphere.
Benefits
The FKE level transmitter stands out for its advanced technical features, specifically designed to ensure accurate, reliable, and long-lasting level measurement in demanding industrial environments. Thanks to its FCX-AIV differential pressure technology, it delivers excellent repeatability and long-term stability, even under harsh conditions.
This industrial level transmitter offers high accuracy of up to ±0.065%, enabling optimal process control. Its 4–20 mA output signal, combined with HART® 7 communication, facilitates integration into supervisory and control systems, while enabling advanced diagnostics and remote configuration.
Designed for versatile use, the FKE level transmitter operates over a wide range of ambient temperatures (-40 to +85 °C) and process temperatures (up to +120 °C), making it suitable for a wide range of industrial applications such as water treatment, the chemical industry, and the energy sector.
Its fast response time of 40 ms ensures responsive measurement, which is essential for dynamic processes.The flexible power supply range of 10.5 to 45 Vdc allows for easy installation in various types of infrastructure.
The transmitter also offers several configuration options, including an LCD display, versions designed for oxygen or chlorine applications, and specific treatments such as degreasing, ensuring that it is perfectly suited to the requirements of each installation.
Finally, its various configuration options— whether local or via HART® —enable rapid commissioning and simplified maintenance, helping to optimize the overall performance of industrial facilities.
| Housing | L- or T-shaped housing |
| Measuring ranges (kPa) [e.max.] | 1 6 32 130 500 3000 |
| Weight per kg (without indicator) | 2-19 |
| Accuracy | ± 0.165% of the measurement range set as standard. An accuracy of ± 0.1% is also available as an option. |
| Materials in contact with the process | Stainless steel 316L, Hastelloy-C, Monel, Tantalum, Hastelloy-C276, Monel 400, Stainless steel 316L + PFA coating, Stainless steel 316L + Gold coating, Titanium, Zirconium |
| Case materials | Low-copper aluminum alloy with polyester or polyester coating or 316L stainless steel. |
| Membrane materials | Stainless steel 316L Hastelloy-C Monel Titanium Zirconium Stainless steel 316L and Gilding |
| Stability | ±0.2% of maximum scale for 10 years. |
| Elevation / Deletion | From -100 to +100% of maximum scale |
| Scale setting range | 1 to 1/100 of maximum scale |
| Measurement cycle | 40 ms |
| Communication protocol | HART™ 7 communication protocol |
| Process temperature | From +40° to +120°C (versions for higher temperatures are available) |
| Ambient temperature | From -40° to +85°C |
| Supply voltage | 10.5 to 45V DC |
| Output signal / Load resistance | 4-20 mA / 250 Ω typical |
| Damping | Configurable between 0.04 and 32 secs |
| Zero and span adjustment | Via external sensor screw, local three-button indicator or HART™ protocol |
| Electrical connections | M20x1.5" / 1/2 - 14 NPT / Pg13.5 |
| Options | Digital indicator, degreasing treatment, oxygen service, chlorine service, additional stainless steel identification plate |