Laser gas analyser - ZSS

Laser gas analysis

Fields of application

The ZSS laser gas analyser is designed for waste incinerators, district heating, industrial boilers and chemical plants.

Features

  • High-precision laser technology
  • Compact size
  • Easy maintenance
  • Fast response
Reference : ZSS Please contact us

Specifications

The laser gas analyser (ZSS) enables continuous measurement of HCl in flue gases in waste incineration plants and industrial waste disposal facilities, NH3 in power plants and denitration plants, CO, CO2 and O2 in steel and chemical plants, with extremely rapid response. As the ZSS is installed directly on the stack through which the gas to be analysed passes (in situ installation), gas conditioning is not required. Highly tolerant to dust, the ZSS can be installed upstream of filtration systems where extractive measurement is generally difficult.

 

General
PrincipleLaser
MethodIn-situ
Measurable components and rangesPlease refer to the table below
Light sourceNear-infrared semiconductor laser
Laser classCLASS 1 (High-temperature version and version with air purge of O2 analysers correspond to CLASS 3B)
Power supply100-240 Vac, 50/60 Hz
Power consumption80 VA
Calibration intervalEvery 6 months (depending on operating environment)
DisplayBacklit LCD
Information displayedComponent, concentration (instantaneous value, average, corrected instantaneous O2 value, corrected average O2 value), alarm
WeightReceiver and transmitter: approx. 10 kg each Controller: approx. 8 kg
DimensionsReceiver (400 (D) x 180 (W) x 155 (H) mm)
Transmitter (400 (D) x 240 (W) x 160 (H) mm)
Controller (137 (D) x 255 (W) x 440 (H) mm)
IP indexIP65

 

Performance
Answer≤ 4 s (≤2 s for high-speed version)
Repeatability≤ ± 1.0% FS (depending on components and scales)
CO + O2 measurement: ±2% FS
Linearity≤ ± 1.0% FS (depending on components and scales)
CO + O2 measurement: ±3% FS
Zero drift≤ ± 2.0% FS for 6 months (depending on component and scale)
CO + O2 measurement: ± 4% FS for 6 months
Effect of interference≤ ± 2.0% PE
Detection limit≤ 1% of minimum scale

 

Input/output signals
Analog outputs4-20 mAcc or 1-5 Vcc, 2 or 4 points
Measured and corrected O2 values. Possibility of switching between instantaneous and average values
Analog inputs4-20 mAcc, 2 points
Sample gas pressure, temperature, flow velocity, O2 content, water concentration, air purge pressure
*Inputs are used for concentration compensation, O2 correction and alarm output.
Digital outputsRelay contact output, 6 points
Low light transmission, high/low limit alarm, fault analyser, calibration in progress/measurement in progress, power failure, installation fault
Digital inputs (optional)Photocoupler voltage input, 3 points
Reset of average value, alternation between instantaneous value and sliding average value, maintenance of remote measurement
Installation environment
Ambient temperature-20 to +55 °C (receiver, transmitter)
-5 to +45 °C (controller)
Ambient humidity≤ 90% RH
Optical path length0.5 to 10 m (0.5 to 5 m for CO + O2 measurement)
Standard flangeJIS 10K, 50A, 100A, DN50/PN10 or ANSI # 150 2B
Purge gasSee table below. Purge gas pressure : ≥ 0.3 MPa
Purge gas flow≥ 20 L/min
Gas conditionsSee table below
Humidity: ≤50 %vol (non-condensing)
Pressure: ± 10 kPa (Consult us for pressures above the limit.)
Dust: Standard version: ≤5 g/m3 (N) High-dust version: ≤20 g/m3 (N)

 

Measurable components and ranges
analyser single beam 1 componentMeasurable componentsScale min.*Max. scale*Gas temperaturePurge gas4th code
HCl10 ppm5000 ppm≤ 400 °CAir instrumentC
NH315 ppm5000 ppm≤ 450 °CW
CO (high scale)2.0%vol100%vol≤ 300 °CA
CO (low scale)200 ppm1%vol≤ 400 °CMr.
CO22.0%vol100%vol≤ 300 °CG
CH4100 ppm100%vol≤ 300 °CR
O210%vol100%vol≤ 300 °CN2P
O2 (high temperature)4%vol100%vol≤ 1200 °CQ
O2 (instrument air purge)25%vol100%vol400 °C ... 1200 °CAir instrumentT
analyser single 2-component harnessCO + CO22.5%vol100%vol≤ 300 °CAir instrumentK
analyser dual 2-component harnessppm CO + O2
(instrument air purge)
CO200 ppm2%vol400 °C ... 1200 °CAir instrumentV
O225%vol100%vol
ppm CO + O2 (high-temperature)
• vol % CO + O2
CO200 ppm2%vol≤ 1200 °CN2U
O25%vol50%vol
%vol CO + O2CO2%vol50%vol≤ 300 °CS
O210%vol100%vol

*The measurement ranges described above are for the optical path of 1 m.

Documentations

Carrousel: Can you reduce boiler operating costs while protecting the environment?

Carousel Download

datasheet : analyser dual-beam ZSS-D gas laser

Datasheet Download

datasheet : analyser single-beam ZSS-S gas laser

Datasheet Download

Brochure: analyser gas laser ZSS-6

Brochures Download

Brochure: analysers gas, reliable solutions for analysis

Brochures Download

Application: How can you save energy and reduce operating costs by optimizing combustion?

Application Sheet Download

Brochure: analyser Laser ZSS

Brochures Download

Brochure: Combustion optimization solutions for boilers

Brochures Download

Brochure: Measures for energy and the environment

Brochures Download

Laser gas analyser - ZSS

Reference : ZSS