Nitrogen gas flow measurement
Fields of application
These nitrogen flowmeters are ideal for companies in the pharmaceutical, chemical and food industries.
Benefits
The FWD-N is an ultrasonic flowmeter that measures nitrogen gas flow in pipes from 25 mm to 80 mm. Nitrogen gas flowmeters are essential for ensuring the smooth running of industrial processes, optimizing their efficiency, detecting possible nitrogen leaks, and preventing waste while guaranteeing safety.
Pipe diameter (mm) | DN25, DN32, DN40, DN50, DN65, DN80, DN100, DN150, DN200 | |||
Supply voltage | 24 V DC ±10% or lithium-ion battery (operating life: approx. 10 years at 20°C) | |||
Power consumption | 24 V DC, 1.5 W or less | |||
Measured fluid | N2 (diameter 25-80 mm) | |||
Fluid temperature | -10°C to 60°C, RH90% or less | |||
Operating pressure | Less than 1 MPagauge pressure) | |||
Scale (instantaneous flow) and accuracy | Diameter (mm) | Scale (m3/h) | Accuracy | |
±2.0% of measurement | ±5.0% of measurement | |||
DN25 | ±0.6-35 | ±3.5-35m3/h | ±0.6-3.5m3/h | |
DN32 | ±1.1-65 | ±6.5-65m3/h | ±1.1-6.5m3/h | |
DN40 | ±1.3-80 | ±8-80m3/h | ±1.3-8m3/h | |
DN50 | ±2.5-150 | ±15-150m3/h | ±2.5-15m3/h | |
DN65 | ±4-240 | ±24-240m3/h | ±4-24m3/h | |
DN80 | ±5-300 | ±30-300m3/h | ±5-30m3/h | |
DN100 | ±10-500 | ±50-500m3/h | ±10-50m3/h | |
DN150 | ±24-1200 | ±120-1200m3/h | ±24-120m3/h | |
DN200 | ±40-2000 | ±200-2000m3/h | ±40-200m3/h | |
Flow conversion accuracy | FWD025-080: ±2.5% of measurement (at 500 kPa, 25°C, dry air) FWD100-200: ±2.0% of measurement (at ≥ 300 kPa) | |||
Display | 1st line | Totalized value (m3) 8-digit, Instantaneous flow (l/mm) 8-digit | ||
2nd line | Instantaneous flow (Nm3/h) 5-digit (4-digit after 2000), Pressure (kPa) 5-digit, Temperature (°C) 3-digit | |||
Outputs (not available with battery supply) | Current output | 4-20 mA DCC (±0.5% PE), max. load resistance. 400Ω, max. current output 22 mA Instantaneous flow, pressure or temperature | ||
Contact output | 2 contact outputs, max. load 24 V DC, 50 mA, max. frequency: 10 Hz,Output 1: pulses (forward), Output 2: pulses (reverse), high/low alarm, system error | |||
Connection | ⌀25, ⌀32 mm | ⌀25 mm: Rc1, ⌀32 mm: Rc1-1/4 | ||
⌀40-⌀80 mm | Flange mounting (JIS10K) | |||
⌀100-⌀200 mm | Flange mounting JIS10K | |||
Mounting conditions (straight lengths) | ⌀25, ⌀32 mm | 20D or more upstream, 5D or more downstream When used for bidirectional measurement, 20D or more downstream and upstream | ||
⌀40-⌀200 mm | 10D or more upstream, 5D or more downstream When used for bidirectional measurement, 10D or more downstream and upstream | |||
Parts in contact with gas | Aluminum alloy, PPS, silicone fluor rubber, etc. | |||
Installation | Indoor or outdoor (IP64 equivalent) | |||
Storage temperature | -20°C to 70°C, non-condensing |